Reason of code of ABB transducer breakdown and means of settlement

  • Time:
  • Click:80
  • source:GAENOR CNC Machining
1, code of ABB transducer breakdown: 0001 reasons: Output electric current exceeded tripping operation to be worth measure: Check electric machinery load. The examination quickens time to check electric machinery and electric machinery cable (include appearance sequence) . Check surroundings qualification. If install the environmental temperature of the place to exceed 40 ° C, so transducer must fall the look is used. 2, code of ABB transducer breakdown: 0002 reasons: Volts d.c. of intermediate electric current is exorbitant. The tripping operation value of circuit volts d.c. is 420 V among 200 V transducer, the tripping operation value of circuit volts d.c. is 840V among 400 V transducer. Measure: Examination overvoltage controller checks the stable state that inputs power source and transient state voltage. Wave of behead of examination apply the brake implement with resistor of apply the brake (if have) . If used wave of behead of apply the brake implement with resistor of apply the brake, must prohibit overvoltage of intermediate circuit dc controls a function. Examination slowdown time undertakes transforming to transducer, increase wave of behead of apply the brake implement with resistor of apply the brake. 3, code of ABB transducer breakdown: 0003 reasons: Transducer IGBT temperature is exorbitant. Tripping operation value is 135 ° C. Measure: Check surroundings qualification. Check fan of refrigeration of cooling air discharge. Check electric machinery power and transducer power. 4, code of ABB transducer breakdown: 0004 reasons: Electric machinery cable or measure of electric machinery short circuit: Examination electric machinery and electric Electromechanical cable 5, code of ABB transducer breakdown: 0006 reasons: Because power source is short of photograph, fuse to burn breakdown of interior of bridge of caustic, commutate or power source voltage is too low, cause intermediate circuit volts d.c. too low. Circuit volts d.c. is owed among 200 V transducer pressing tripping operation to be worth is 162 V, circuit volts d.c. owes among 400 V transducer press tripping operation measure: The value is 308 V. Measure: The examination is owed press controller. Check power source and fuse. 6, code of ABB transducer breakdown: 0007 reasons: Imitate inputs AI1 under by parameter 3021, the bounds that AI1 FAULT LIMIT defines is worth. Measure: Check the parameter setting of breakdown function. Order and degree of voltage of signal of examination imitate control is proper. Check wiring. 7, code of ABB transducer breakdown: 0008 reasons: Imitate inputs AI2 under by parameter 3022. The bounds that AI2 FAULT LIMIT defines is worth. Measure: Check the parameter setting of breakdown function. Order and degree of voltage of signal of examination imitate control is proper. Check wiring. 8, code of ABB transducer breakdown: 0009 reasons: 1, electric machinery is too lukewarm, the reason may be power of overload, electric machinery too small, refrigeration is not worth or start data mistake. 2, the breakdown that temperature measured value had exceeded electric machinery to be defined by parameter 3504 FAULT LIMIT is restricted to be worth. Reason 1 means of settlement: Examination electric machinery is rated parameter, laden with refrigeration. The examination starts data. Check setting of breakdown function parameter. Reason 2 means of settlements: Examination breakdown is restricted to be worth. The examination passes parameter (the model of the sensor that 3501 SENSOR TYPE) installs. Make electric machinery cooling. Make sure system of electric machinery refrigeration is regular: Check clean and cooling fan, cool surface to wait. 9, code of ABB transducer breakdown: 0010 reasons: Be chosen to be effective control ground control dish of break down communication. Measure: The examination controls dish of join. Check the parameter setting of breakdown function. The examination controls dish of connector. Change the control on installing plate dish. If transducer is in exterior control mode (REM) , and transducer is controlled to pass by the setting dish receive start / stop, direction commands or set-point, so: 10 START/STOP/DIR of examination parameter group and 11 REFERENCE Selec (give an option) setting. CNC Milling CNC Machining